


default search action
IEEE Transactions on Medical Imaging, Volume 13
Volume 13, Number 1, March 1994
- Aiman A. Abdel-Malek, Fathy F. Yassa:

An adaptive gating approach for X-ray dose reduction during cardiac interventional procedures. 2-12 - Adrie C. M. Dumay, Johan H. C. Reiber, Jan J. Gerbrands:

Determination of optimal angiographic viewing angles: basic principles and evaluation study. 13-24 - Wei Qian, Laurence P. Clarke, Maria Kallergi, Robert A. Clark:

Tree-structured nonlinear filters in digital mammography. 25-36 - Reza Momenan, Robert F. Wagner, Brian S. Garra, Murray H. Loew, Michael F. Insana:

Image staining and differential diagnosis of ultrasound scans based on the Mahalanobis distance. 37-47 - Claire Pellot, Alain Herment, Marc Sigelle, Patrick Horain

, Henri Maître, Pierre Peronneau:
A 3D reconstruction of vascular structures from two X-ray angiograms using an adapted simulated annealing algorithm. 48-60 - Thinh V. Nguyen, Jack Sklansky:

Reconstructing the 3-D medial axes of coronary arteries in single-view cineangiograms. 61-73 - Michael A. Guttman, Jerry L. Prince, Elliot R. McVeigh:

Tag and contour detection in tagged MR images of the left ventricle. 74-88 - John M. Ollinger:

Maximum-likelihood reconstruction of transmission images in emission computed tomography via the EM algorithm. 89-101 - Djamel Boulfelfel, Rangaraj M. Rangayyan, Leszek J. Hahn, Reinhard Kloiber, Gopinath R. Kuduvalli:

Two-dimensional restoration of single photon emission computed tomography images using the Kalman filter. 102-109 - Zang Hee Cho, Ed X. Wu

, Sadek K. Hilal:
Weighted backprojection approach to cone beam 3D projection reconstruction for truncated spherical detection geometry. 110-121 - Senthil Kumar, Dmitry B. Goldgof:

Automatic tracking of SPAMM grid and the estimation of deformation parameters from cardiac MR images. 122-132 - Thomas K. F. Foo, Nancy S. Grigsby, James D. Mitchell, Beth E. Slayman:

SNORE: spike noise removal and detection. 133-136 - Volker Tresp, Rodney Snell, Arthur F. Gmitro:

Videographic tomography. II. Reconstruction with fan-beam projection data. 137-143 - Kensuke Sekihara, Bernhard Scholz, Herbert Bruder:

Reconstructing current distributions from biomagnetic measurements under large external noise disturbances. 144-151 - Ergin Atalar

, Elliot R. McVeigh:
Optimization of tag thickness for measuring position with magnetic resonance imaging. 152-160 - Hamid Soltanian-Zadeh

, Romesh Saigal, Joe P. Windham, Andrew E. Yagle, David O. Hearshen:
Optimization of MRI protocols and pulse sequence parameters for eigenimage filtering. 161-175 - B. T. A. McKee, A. W. Dickson, D. C. Howse:

Performance of QPET, a high-resolution 3D PET imaging system for small volumes. 176-185 - Michel Defrise, Rolf Clack:

A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection. 186-195 - Hiroyuki Kudo

, Tsuneo Saito:
Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits. 196-211
Volume 13, Number 2, June 1994
- Ping-Chun Chiao, W. Leslie Rogers, Neal H. Clinthorne, Jeffrey A. Fessler, Alfred O. Hero III:

Model-based estimation for dynamic cardiac studies using ECT. 217-226 - Ping-Chun Chiao, W. Leslie Rogers, Jeffrey A. Fessler, Neal H. Clinthorne, Alfred O. Hero III:

Model-based estimation with boundary side information or boundary regularization [cardiac emission CT]. 227-234 - Karun P. Philip, Edwin L. Dove, David D. McPherson, Nina L. Gotteiner, William Stanford, Krishnan B. Chandran:

The fuzzy Hough transform-feature extraction in medical images. 235-240 - Karun P. Philip, Edwin L. Dove, David D. McPherson, Nina L. Gotteiner, Michael J. Vonesh, William Stanford, Judd E. Reed, John A. Rumberger, Krishnan B. Chandran:

Automatic detection of myocardial contours in cine-computed tomographic images. 241-253 - Maï Khuong Nguyen, Ali Mohammad-Djafari

:
Bayesian approach with the maximum entropy principle in image reconstruction from microwave scattered field data. 254-262 - Liang Shen, Rangaraj M. Rangayyan, J. E. Leo Desautels:

Application of shape analysis to mammographic calcifications. 263-274 - John Cardillo, Maher A. Sid-Ahmed:

An image processing system for locating craniofacial landmarks. 275-289 - Jeffrey A. Fessler:

Penalized weighted least-squares image reconstruction for positron emission tomography. 290-300 - Ralph Highnam, J. Michael Brady, Basil Shepstone:

Computing the scatter component of mammographic images. 301-313 - Zhengrong Liang:

Detector response restoration in image reconstruction of high resolution positron emission tomography. 314-321 - Jean-Philippe Thirion:

Direct extraction of boundaries from computed tomography scans. 322-328 - Mark F. Smith, Ronald J. Jaszczak:

Simultaneously constraining SPECT activity estimates with primary and secondary energy window projection data. 329-337 - Nevzat Güneri Gençer

, Mustafa Kuzuoglu, Yusuf Ziya Ider:
Electrical impedance tomography using induced currents. 338-350 - Ingrid Carlbom, Demetri Terzopoulos, Kristen M. Harris

:
Computer-assisted registration, segmentation, and 3D reconstruction from images of neuronal tissue sections. 351-362 - Stephen J. Glick, B. C. Penney, Michael A. King, Charles L. Byrne:

Noniterative compensation for the distance-dependent detector response and photon attenuation in SPECT imaging. 363-374 - Jun Wang, H. K. Huang:

Film digitization aliasing artifacts caused by grid line patterns. 375-385 - Samuel Moon-Ho Song, Richard M. Leahy, Douglas P. Boyd, Bruce H. Brundage, Sandy Napel:

Determining cardiac velocity fields and intraventricular pressure distribution from a sequence of ultrafast CT cardiac images. 386-397 - Michael J. Cree, Philip J. Bones:

Towards direct reconstruction from a gamma camera based on Compton scattering. 398-407 - P. Duffy Cutler, Edward J. Hoffman:

Use of digital front-end electronics for optimization of a modular PET detector. 408-418 - C. Q. Lan, W. Xiong:

An iterative method of ultrasonic reflection mode tomography. 419-425
Volume 13, Number 3, September 1994
- Jean-Pierre V. Guédon, Yves Bizais:

Bandlimited and Haar filtered back-projection reconstructions. 430-440 - Zhengrong Liang, James R. MacFall, Donald P. Harrington:

Parameter estimation and tissue segmentation from multispectral MR images. 441-449 - Brian C. S. Tom, Serafim N. Efstratiadis, Aggelos K. Katsaggelos

:
Motion estimation of skeletonized angiographic images using elastic registration. 450-460 - Michael D. Herr, Joseph J. McInerney, Dennis G. Lamser, Gary L. Copenhaver:

A flying spot X-ray system for Compton backscatter imaging. 461-469 - Torfinn Taxt, Arvid Lundervold

:
Multispectral analysis of the brain using magnetic resonance imaging. 470-481 - Larry E. Antonuk, John M. Boudry, Weidong Huang, Kwok Leung Lam, Edward J. Morton, Randall K. T. Haken, John Yorkston, Neal H. Clinthorne:

Thin-film, flat-panel, composite imagers for projection and tomographic imaging. 482-490 - Robin N. Strickland:

Tumor detection in nonstationary backgrounds. 491-499 - Keith A. Wear

, Robert F. Wagner, Brian S. Garra:
High resolution ultrasonic backscatter coefficient estimation based on autoregressive spectral estimation using Burg's algorithm. 500-507 - Gregory P. Otto, Weng Cho Chew:

Time-harmonic impedance tomography using the T-matrix method. 508-516 - Erik Steen, Bjørn Olstad:

Volume rendering of 3D medical ultrasound data using direct feature mapping. 517-525 - Richard E. Carson, Yuchen Yan, BettyAnn Chodkowski, Tieng K. Yap, Margaret E. Daube-Witherspoon:

Precision and accuracy of regional radioactivity quantitation using the maximum likelihood EM reconstruction algorithm. 526-537 - Keshi Chen, Tenkasi V. Ramabadran:

Near-lossless compression of medical images through entropy-coded DPCM. 538-548 - Gengsheng L. Zeng, Grant T. Gullberg:

A backprojection filtering algorithm for a spatially varying focal length collimator. 549-556 - Haiguang Chen, Andrew Li, Leon Kaufman, James Hale:

A fast filtering algorithm for image enhancement. 557-564 - Alain Venot, Luc Pronzato, Eric Walter:

Comments about the coincident bit counting (CBC) criterion for image registration. 565-566 - Eugene Veklerov:

How to compute the difference between tomographic images. 566-569 - Valen E. Johnson:

A note on stopping rules in EM-ML reconstructions of ECT images. 569-571
Volume 13, Number 4, December 1994
- Tinglan Ji, Malur K. Sundareshan, Hans Roehrig:

Adaptive image contrast enhancement based on human visual properties. 573-586 - Qiang Chen

, Kunio Sawaya, Toru Uno, Saburo Adachi, Hisaaki Ochi, Etsuji Yamamoto:
A three dimensional analysis of slotted tube resonator for MRI. 587-593 - Andy Adler, Robert Guardo:

A neural network image reconstruction technique for electrical impedance tomography. 594-600 - H. Malcolm Hudson, Richard S. Larkin:

Accelerated image reconstruction using ordered subsets of projection data. 601-609 - Robin J. Smith, Joel S. Karp, Gerd Muehllehner:

The countrate performance of the volume imaging PENN-PET scanner. 610-618 - Liang Zhou, Mark S. Rzeszotarski, Lawrence J. Singerman, Jeanne M. Chokreff:

The detection and quantification of retinopathy using digital angiograms. 619-626 - Xiaolong Ouyang, Wing Hung Wong, Valen E. Johnson, Xiaoping Hu

, Chin-Tu Chen:
Incorporation of correlated structural images in PET image reconstruction. 627-640 - Lingxiong Shao, Richard Freifelder, Joel S. Karp:

Triple energy window scatter correction technique in PET. 641-648 - Martin J. Lercher

, Klaus Wienhard:
Scatter correction in 3-D PET. 649-657 - Joseph J. McInerney, Dennis G. Lamser, Michael D. Herr:

A device for a noninvasive evaluation of coronary bypass grafts. 658-666 - Haiguang Chen, Hector E. Avram, Leon Kaufman, James Hale, David M. Kramer:

T2 restoration and noise suppression of hybrid MR images using Wiener and linear prediction techniques. 667-676 - Zhi-Pei Liang, Paul C. Lauterbur:

An efficient method for dynamic magnetic resonance imaging. 677-686 - Erkan U. Mumcuoglu, Richard M. Leahy, Simon R. Cherry, Zhenyu Zhou:

Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images. 687-701 - Jean-Baptiste Poline, Bernard Mazoyer

:
Analysis of individual brain activation maps using hierarchical description and multiscale detection. 702-710 - B. T. A. McKee, L. G. Hiltz, P. J. Harvey:

Signal-to-noise ratios for attenuation correction in PET imaging. 711-715 - Alex P. Zijdenbos, Benoit M. Dawant, Richard A. Margolin, Andrew C. Palmer:

Morphometric analysis of white matter lesions in MR images: method and validation. 716-724 - Andrew F. Laine, Sergio Schuler, Jian Fan, Walter Huda:

Mammographic feature enhancement by multiscale analysis. 725-740

manage site settings
To protect your privacy, all features that rely on external API calls from your browser are turned off by default. You need to opt-in for them to become active. All settings here will be stored as cookies with your web browser. For more information see our F.A.Q.


Google
Google Scholar
Semantic Scholar
Internet Archive Scholar
CiteSeerX
ORCID














